Filter Results By:

Products

Applications

Manufacturers

Showing results: 691 - 705 of 852 items found.

  • RS232 9 Way D-Type lead

    1081-001 - Pickering Interfaces Ltd.

    Pickering Interfaces Series 1000 SIM Reed Relay Cards offer a choice of switching configurations using low cost industry standard SIM connectors. They are ideal for placing switching systems in fixtures close to the unit under test.

  • SIMRC - RS232 to I2C Converter PCB

    1080-001 - Pickering Interfaces Ltd.

    Pickering Interfaces Series 1000 SIM Reed Relay Cards offer a choice of switching configurations using low cost industry standard SIM connectors. They are ideal for placing switching systems in fixtures close to the unit under test.

  • Primary Current Injection Test Sets

    T&R Test Equipment Ltd.

    Our primary current injection test sets cover from 750A through to 6000A. Available in single phase, testing applications include testing and timing of under and over current relays, circuit breakers and CT ratio testing.

  • PXI SPDT Switch: 64-ch, 100 Vrms / 1A, Reed Relays

    M9131A - Keysight Technologies

    The M9131A is a high-density, general purpose switch with 64 independent, single-pole, double-throw (Form C) switches in a single PXI module. This module can be used to cycle power to products under test, control indicator and status lights, or actuate external power relays and solenoids. The high-speed, long-life reed relays can handle 100 Vrms and 1 A, with up to 3 W maximum power. Choose from the durable connector block or standard cable connections.

  • 16 Channel Multiplexer (2/4-wire) Module for 34970A/34972A

    34902A - Keysight Technologies

    The Keysight 34902A module for the 34970A/34972A Data Acquisition/Switch Unit employs reed relays to achieve scan rates up to 250 channels-per-second. Use this module for high-throughput automated test applications as well as high-speed data logging and monitoring tasks.

  • Modular Relay Board

    Alliance Support Partners, Inc.

    An increasing number of electronics products are being assembled in panels of 8 or more to minimize production cost. These products are typically tested with in-circuit tests (ICT) followed by power-on functional tests. Normally, ICT requires isolation of power and ground while measurements are being performed. Functional tests, including in-system programming (ISP), require board power to be applied. The Modular Relay Board (MRB) is designed to switch power onto each individual board and to disconnect sensitive signals during functional test.

  • PXI Multiplexer Switch Module

    NI

    PXI Multiplexer Switch Modules are ideal for high-channel-count applications that need to connect measurement or signal generation instruments to various test points on devices or units under test(DUTs or UUTs). PXI Multiplexer Switch Modules use a variety of relay types, including electromechanical armature relays, reed relays, field-effect transistor(FET) relays, and solid-state relays, each with their own benefits, allowing you to choose a multiplexer that fits your requirements. To program the switches, you can use the IVI-compliant NI-SWITCH driver software, complete with help documentation, example programs, and a soft front panel application for interactive control of switches. For intelligent management of complex switch systems, NISwitch Executive provides additional software tools to help you design, build, and deploy your switching system.

  • PXI RF Multiplexer Switch Module

    NI

    PXI RF Multiplexer Switch Modules are ideal for high-channel-count applications that need to connect measurement or signal generation instruments to various test points on devices or units under test(DUTs or UUTs). PXI RF Multiplexer Switch Modules use a variety of relay types, including electromechanical armature relays, reed relays, field-effect transistor(FET) relays, and solid-state relays, each with their own benefits, allowing you to choose a multiplexer that fits your requirements. To program the switches, you can use the IVI-compliant NI-SWITCH driver software, complete with help documentation, example programs, and a soft front panel application for interactive control of switches. For intelligent management of complex switch systems, NISwitch Executive provides additional software tools to help you design, build, and deploy your switching system.

  • Ratemeter

    TR400 - Electro-Sensors, Inc.

    Full-logic control process ratemeter displays speed and direction of rotating equipment. • Displays rate or time-in-process • Detects and converts 0.01 to 4,000 Hz signal input • Optional relay outputs: 2 or 6 • Optional analog output: 4-20 mA or 0-10 V • Completely field programmable • Full diagnostic functions • Single-channel or bi-directional (quadrature) decoding • Front panel reverse direction indication • 3 programmable inputs • Built-in relay test function

  • Waveguide Electromechanical Relay Switches

    Pasternack Enterprises, Inc.

    Pasternack's waveguide electromechanical relay switches offer full waveguide performance covering C, X, Ku, K and Ka frequency bands. Waveguide electromechanical relay switch components from Pasternack cover various frequency ranges from 5.85 GHz to 40 GHz depending on the model. These waveguide switches are ideal for applications that include electronic warfare, electronic countermeasures, microwave radio, VSAT, SATCOM, radar, research and development, space systems and test instrumentation.

  • LXI 75Ω RF Matrix - 1GHz

    Pickering Interfaces Ltd.

    The design is fully scalable, allowing a variety of matrix sizes to be offered in a single family. It maintains a close path loss match for all routes through the matrix, minimizing the calibration effort that has to be invested by users in optimizing their test system performance. The design is non-blocking Y to X (or X to Y) allowing any input to be connected to any output. The construction is based on high quality electromechanical relays which provide a fast operating time compared to microwave relays.

  • 20 Channel Actuator/GP Switch Module for 34970A/34972A

    34903A - Keysight Technologies

    The Keysight 34903A is a general-purpose switch module for the 34970A/34972A Data Acquisition/Switch Unit. It has 20 independent single-pole, double-throw (SPDT) relays and is used to cycle power to products under test, control indicator and status lights, and to actuate external power relays and solenoids. Combine it with matrix and multiplexer modules to build custom switch systems. Its 300 V, 1 A contacts can handle up to 50 W, enough for many power line switching applications.

  • Primary Current Injection Testers

    Hilkar

    Primary Current Injection Tester is designed for testing protective relay and circuit breakers and also testing the turns ratio of current transformers at high variable currents. A test current is injected into the primary side of a system to determine how the system behaves at particular levels of current. This test makes it possible to determine whether the relay will trip and how long the current needs to flow before the trip is initiated.

  • Function Test Systems

    MK Test Systems Ltd.

    These specialist Automeg models test the function and integrity of wiring harnesses combined with active components such as relays, switches, contactors, diodes, LEDS, actuators and other active components.Our software takes the complex and traditionally long task of creating functional tests away from the test engineer and allows these to be created automatically, from existing ECAD data and our component library and automated software routines. All the different routes and subtests are automatically calculated in seconds.

  • FTL Test Block

    SecuControl inc.

    FTL testblock with dust cover and current disconnect pinThe FTL is a test block for interfacing substation devices (protection relays, fault recorders, revenue meters, ... ) to the voltage and current transformers and to other equipment on the system side of a power grid. The FTL test block uses disconnect pins to isolate the substation devices from the system side equipment. Once isolated, secondary injection can be performed using banana jacks on the front side of the test block.

Get Help